Where applicable it provides assurance that electrostatic discharge sensitive devices have been handled and packed under conditions that meet the administrative and technical requirements of the ANSIESD S20.20:2014 and BS EN 61340-5-1:2007 Electrostatic Control Standards.Specifically, we will connect to a FX3GE-24M PLC using an Ethernet connection.Configuration is possible using a local network connection or from an exported configuration data file via USB.
Regardless of the method used, the required configuration methods will be the same. Mitsubishi Plc Software How To Configure TheThis example will illustrate how to configure the router using a local network connection. Once the username and password has been successfully entered the MAC IDs of the router Ethernet interfaces will populate in the Routers found window. If this is the first time configuring the router use the default user (admin) and password (admin). The default username and password along with the MAC IDs of each Ethernet interface is printed on the nameplate of the router. An internet connection is required to set up a VPN connection to the remote PC running Combivis Connect. The C6 Router family can support either wired internet connections or wireless internet connections via cellular networks. It is possible to assign multiple IP addresses to the LAN port to reach devices on separate subnets. Once a VPN connection is established all devices on each subnet will be reachable. Each router must be assigned a name and location within a licensed Domain. Select the Apply option at the bottom of the configuration screen. Once the router reboots it will establish appear Online in the Domain device tree. Select Connect at the bottom of the Device access window or right-click on the C6 Router in the device tree and select Connect VPN to establish a VPN connection. Once a VPN connection has been established, the virtual ethernet port utilized by Combivis Connect will be assigned an IP address within the LAN network. All remote devices are now reachable using the VPN connection. Connection settings are displayed and configured in the Connection Destination view in the navigation window. Select name of the connection under Current Connection to configure the connection settings. Combivis Connect uses a virtual ethernet port for communication to the remote PLC network. After selecting this the IP address and CPU type will populate. If you have further questions about this process or would like to contact us about testing andor purchasing an industrial router, contact us using the form below. A KEB application engineer will be in contact with you shortly.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |